Products Affected Systems Updated: - ProSignia, ProSignia VS, ProSignia 200/300/500 - Proliant 800/850R/1000/1200/1500/1600/1850R/2000/2500/3000/4000/4500/5000/5500/ 6000/6500/7000, Rack-Mountable Proliant Servers or Systempro, Systempro/e, Systempro/LT, Systempro/XL Options Affected: - Compaq SMART-2 Controller - Compaq SMART ARRAY 3xxx & 221 Controllers - Compaq Fibre Array Controller - Compaq SCSI Drives on the SMART-2, Smart Array 3xxx & 221 Controllers - Compaq SCSI Drives on the Fast-SCSI-2 Controller - Compaq SCSI Drives on the Fast-Wide SCSI-2 Controller - Compaq SCSI Drives on the Wide-Ultra SCSI-3 Controller - Compaq SCSI Drives on the Dual Channel Wide-Ultra SCSI-3 Controllers - Compaq SCSI Drives on the Fibre Array Controller
Supersedes SP7342 (Full release of Option ROMPaq 2.45) SP8560 (Single diskette release of Option ROMPaq 2.49 diskette #1)

  Download sp8562.exe  


Readme

SOFTPAQ NUMBER:  SP8562
PART NUMBER:  276780-001
FILE NAME:  N/A
TITLE:  Options ROMPaq
VERSION:  2.51 Rev A
LANGUAGE:  English

CATEGORY:  Rompaqs
DIVISIIONS:  Systems

PRODUCTS AFFECTED:  
Systems Updated:
- ProSignia, ProSignia VS, ProSignia 200/300/500
- Proliant 800/850R/1000/1200/1500/1600/1850R/2000/2500/3000/4000/4500/5000/5500/
  6000/6500/7000, Rack-Mountable Proliant Servers or Systempro,
  Systempro/e, Systempro/LT, Systempro/XL

Options Affected:
- Compaq SMART-2 Controller
- Compaq SMART ARRAY 3xxx & 221 Controllers
- Compaq Fibre Array Controller
- Compaq SCSI Drives on the SMART-2, Smart Array 3xxx & 221 Controllers
- Compaq SCSI Drives on the Fast-SCSI-2 Controller
- Compaq SCSI Drives on the Fast-Wide SCSI-2 Controller
- Compaq SCSI Drives on the Wide-Ultra SCSI-3 Controller
- Compaq SCSI Drives on the Dual Channel Wide-Ultra SCSI-3 Controllers
- Compaq SCSI Drives on the Fibre Array Controller


OPERATING SYSTEM:  N/A

SYSTEM CONFIGURATION:  N/A

EFFECTIVE DATE:  March 15, 1999

ELECTRONIC DISTRIBUTION ALLOWED:  Yes

SOFTPAQ UTILITY VERSION:  2.X

SUPERSEDES:  SP7342 (Full release of Option ROMPaq 2.45) 
             SP8560 (Single diskette release of Option ROMPaq 2.49 
                     diskette #1)

DESCRIPTION:  The Options ROMPaq diskettes allow a user to
upgrade the ROM Firmware images for Compaq System product Options.  The
Options ROMPaq consists of ten (10) diskettes:

	Disk 1 - Options ROMpaq Firmware Upgrade Diskette for the 
		 Compaq SMART-2, SMART ARRAY 3100ES, SMART ARRAY 
		 3200 and SMART ARRAY 221 Controllers

	Disk 2 - Options ROMpaq Firmware Upgrade Diskette for 
		 Compaq SCSI Hard Drives

	Disk 3 - Options ROMpaq Firmware Upgrade Diskette for 
		 Additional Compaq SCSI Hard Drives

	Disk 4 - Options ROMpaq Firmware Upgrade Diskette for 
		 Extra Compaq SCSI Hard Drives

	Disk 5 - Options ROMpaq Firmware Upgrade Diskette for 
		 Supplementary Compaq SCSI Hard Drives

	Disk 6 - Options ROMpaq Firmware Upgrade Diskette for 
		 Compaq SCSI CD Storage System

	Disk 7 - Options ROMpaq Firmware Upgrade Diskette for the
		 Compaq Fibre Array Controller and Compaq SCSI 
		 Hard Drives on the Compaq Fibre Array Controller
                                                                              
	Disk 8 - Options ROMpaq Firmware Upgrade Diskette for 
		 Additional Compaq SCSI Hard Drives on the Compaq 
		 Fibre Array Controller

	Disk 9 - Options ROMpaq Firmware Upgrade Diskette for
		 Extra Compaq SCSI Hard Drives on the Compaq Fibre
		 Array Controller

	Disk 10 - Options ROMpaq Firmware Upgrade Diskette for
		  Supplementary Compaq SCSI Hard Drives on the
		  Compaq Fibre Array Controller

* NOTE: This Option ROMPaq does not contain firmware images for any
        Compaq tape drives. Obtain SoftPaq SP8050 to
        get the latest tape drive firmware from 
        Compaq.

* NOTE: This Option ROMPaq does not contain firmware images for the 
        Compaq SMART Controller. Obtain SoftPaq SP8560 to get firmware
        for this controller.


Enhancements/Fixes:
- Added support for stamping M&P data on Compaq hard drives.  This process
  occurs during device discovery and does not require a flash operation.

* NOTE: This operation only works on Compaq SCSI hard drives attached to
	SMART-2, SMART ARRAY 3xxx or 221 Controllers.

- Upgraded SMART Array 3100ES and 3200 Controller firmware from 3.08 to 4.02 to
  add redundant controller support for SMART Array 3100ES.
- Added support for Smart Array 221 Controller. Firmware version 3.22, first 
  shipping version.
- Upgraded Compaq Fibre Array Controller firmware from 1.20 to 1.22 to address
  the following issues:

	- Controller lock-up if there were more than 3 logical volumes present.
	- Fixed hang problem caused by sending various read-type commands but asking
	  that 0 bytes be returned.

- Upgraded DDRS345 and DDRS391 hard drive firmware from S97A to S99C.
- Upgraded HD00441730, HD00431731, HD0094172B, HD0093172C, HC01841729 and HC0183172A
  hard drive firmware from 3207 to 3208.


  CONTROLLER FIRMWARE
  ===================
  SMART-2 Controller      version 3.08 (disk 1)
  SMART ARRAY 3100ES	  version 4.06 (disk 1)
  SMART ARRAY 3200	  version 4.06 (disk 1)
  SMART ARRAY 221	  Version 3.22 (disk 1)
  Fibre Array Controller  version 1.22 (disk 7)


	
  HARD DRIVES
  ===========
  Version:
	3208 - model HD00441730, HD00431731 [10K 4.3GB] (disk 2 & 7)
	3208 - model HD0094172B, HD0093172C [10K 9.1GB] (disk 2 & 7)
	3208 - model HD01841729, HD0183172A [10K 18.2GB] (disk 2 & 7) 
	S99C - model DDRS34560W [4.3GB], DDRS39130W [9.1GB] (disk 5)
	0814 - model MAA3182SP [18.2gb], MAA3182SC [18.2GB], MAB3091SP [9.1GB],
	       MAB3091SC [9.1GB], MAB3045SP [4.3GB], MAB3045SC [4.3GB]. (disk 5 & 10)
	B004 - model ST19101WC [9.1GB] (disk 5 & 10)
	1.40 - model WDE9100S [9.1GB]  (disk 5 & 10)
	1.70 - model WDE2170 [2.1GB], WDE2170W [2.1GB], WDE2170S [2.1GB],
  	       WDE4360 [4.3GB], WDE4360W [4.3GB], WDE4360S [4.3GB] (disk 5 & 10)
	AF04 - model ST34501W [4.3GB], ST34501WC [4.3GB] (disk 5 & 10)
	5858 - model DCHS04Y [4.3GB], DCHS09Y [9.1GB], DCHS04U [4.3GB]
	       (disk 3 & 8)
	03F1 - model DGHS09U [9.1GB], DGHS09Y [9.1GB], DGHS18Y [18.2GB] 
	       (disk 3 & 8)
	9A10 - model ST19171N [9.1GB], ST19171W [9.1GB], ST19171WC [9.1GB]
	       (disk 4 & 9)
	0940 - model ST32171N [2.1GB], ST32171W [2.1GB], ST34371N [4.3GB],
	       ST34371W [4.3GB] (disk 5 & 10)
	0942 - model ST32171WC [4.3GB], ST34371WC [4.3GB] (disk 5 & 10)
	4343 - model DFHSS2W [2.1GB], DFHSS2F [2.1GB], DFHSS4W [4.3GB], 
	       DFHSS4F [4.3GB] (disk 3 & 8)
	L915 - model XP34300W [4.3GB] (disk 3 & 8)
	L915 - model XP32150W [2.1GB] (disk 3 & 8)
	6317 - model ST32550N [2.1GB] (disk 4 & 9)
	6416 - model ST32550W [2.1GB] (disk 4 & 9)
	5217 - model ST15150N [4.3GB] (disk 4 & 9)
	6216 - model ST15150W [4.3GB] (disk 4 & 9)
	442C - model DSP3107LS [1.0GB] (disk 3 & 8)
  
  CD STORAGE SYSTEM
  =================
  version 3080 (disk 6)


  NOTE:   Multiple firmware versions exist for these products. This
          ROMpaq utility will identify and upgrade the correct firmware to the
          specific OEM tape hardware product.

HOW TO USE:

1. Obtain ten (10) formatted 1.44-MB diskettes.

2. Download the SoftPaq to a directory on your hard drive and change 
to that directory.  The file that is downloaded is an executable with 
a filename based on the SoftPaq Number above.

3. From that drive and directory, execute the downloaded file 
and follow the on-screen instructions.  You will be prompted to 
insert the formatted diskettes in a drive to create the diskettes.

4. After the diskettes have been created, you may delete the  
SoftPaq file downloaded in step 2.

5. The Options ROMPaq diskettes are self-booting diskettes.  Place each
ROMPaq diskette into your drive A: diskette drive and power cycle your
system to begin updating the appropriate components.

Copyright 1999, Compaq Computer Corporation.  All rights reserved.

Product names mentioned herein may be trademarks and/or registered trademarks 
of their respective companies.


PaqPlace — Compaq SoftPaq driver and software preservation archive. Not affiliated with Compaq or Hewlett-Packard.
Compaq and SoftPaq are trademarks of Hewlett-Packard Development Company, L.P.
All software provided as-is. Use at your own risk.
Home