| PaqPlace
For your Compaq |
Compaq SoftPaq Driver & Software Archive |
|
|
|
SP8050 — Options ROMPaq
| SoftPaq Number |
SP8050 |
| Filename |
SP8050.EXE |
| Size |
5549K |
| Date |
September , 1998 |
| Version |
2.47 Rev B |
| Operating System |
All |
| Products Affected |
Systems Updated: - ProSignia, ProSignia VS, ProSignia 200/300/500 - Proliant 800/850R/1000/1200/1500/1600/1850R/2000/2500/3000/4000/4500/5000/5500/ 6000/6500/7000, Rack-Mountable Proliant Servers or Systempro, Systempro/e, Systempro/LT, Systempro/XL Options Affected: - Compaq SMART and SMART-2 Controller - Compaq Fibre Array Controller - Compaq SCSI Drives on the SMART and SMART-2 Controllers - Compaq SCSI Drives on the Fast-SCSI-2 Controller - Compaq SCSI Drives on the Fast-Wide SCSI-2 Controller - Compaq SCSI Drives on the Wide-Ultra SCSI-3 Controller - Compaq SCSI Drives on the Dual Channel Wide-Ultra SCSI-3 Controllers - Compaq DAT Drives on the Fast-SCSI-2 Controller - Compaq DAT Drives on the Fast-Wide SCSI-2 Controller - Compaq DAT Drives on the Wide-Ultra SCSI-3 Controller - Compaq DAT Drives on the Dual Channel Wide-Ultra SCSI-3 Controllers |
| Supersedes |
SP7342 (Full release of Option ROMPaq 2.45) SP7344 (Single diskette release of Option ROMPaq 2.46 diskette #1) |
Readme
SOFTPAQ NUMBER: SP8050
PART NUMBER: 276780-001
FILE NAME: N/A
TITLE: Options ROMPaq
VERSION: 2.47 Rev B
LANGUAGE: English
CATEGORY: Systems/ROMPaqs
PRODUCTS AFFECTED:
Systems Updated:
- ProSignia, ProSignia VS, ProSignia 200/300/500
- Proliant 800/850R/1000/1200/1500/1600/1850R/2000/2500/3000/4000/4500/5000/5500/
6000/6500/7000, Rack-Mountable Proliant Servers or Systempro,
Systempro/e, Systempro/LT, Systempro/XL
Options Affected:
- Compaq SMART and SMART-2 Controller
- Compaq Fibre Array Controller
- Compaq SCSI Drives on the SMART and SMART-2 Controllers
- Compaq SCSI Drives on the Fast-SCSI-2 Controller
- Compaq SCSI Drives on the Fast-Wide SCSI-2 Controller
- Compaq SCSI Drives on the Wide-Ultra SCSI-3 Controller
- Compaq SCSI Drives on the Dual Channel Wide-Ultra SCSI-3 Controllers
- Compaq DAT Drives on the Fast-SCSI-2 Controller
- Compaq DAT Drives on the Fast-Wide SCSI-2 Controller
- Compaq DAT Drives on the Wide-Ultra SCSI-3 Controller
- Compaq DAT Drives on the Dual Channel Wide-Ultra SCSI-3 Controllers
OPERATING SYSTEM: N/A
SYSTEM CONFIGURATION: N/A
EFFECTIVE DATE: September , 1998
ELECTRONIC DISTRIBUTION ALLOWED: Yes
SOFTPAQ UTILITY VERSION: 2.X
SUPERSEDES: SP7342 (Full release of Option ROMPaq 2.45)
SP7344 (Single diskette release of Option ROMPaq 2.46
diskette #1)
DESCRIPTION: The Options ROMPaq diskettes allow a user to
upgrade the ROM Firmware images for Compaq System product Options. The
Options ROMPaq consists of eight (5) diskettes:
Disk 1 - Options ROMpaq Firmware Upgrade Diskette for the
Compaq SMART and SMART-2 SCSI Array Controllers and
The Compaq Fibre Array Controller
Disk 2 - Options ROMpaq Firmware Upgrade Diskette for
Compaq Hard Drives
Disk 3 - Options ROMpaq Firmware Upgrade Diskette for
Compaq Additional Hard Drives
Disk 4 - Options ROMpaq Firmware Upgrade Diskette for
Compaq Extra Hard Drives
Disk 5 - Options ROMpaq Firmware Upgrade Diskette for
Compaq SCSI DAT Drives and SCSI Tape Drives
This release of Options ROMPaq does not contain support for upgrading hard drives
in a Compaq Fibre Array System.
Enhancements/Fixes:
- Upgraded SMART-2 Controller firmware from Version 2.08 to 2.14 to correct
the following potential issues:
- Changed Monitor and Performance tests that run after a hot plug
to correct false threshold violations resulting in a pre-failure event
on WDExxxx hard drives
- Reset Monitor and Performance factory seek time and false threshold exceeded
flag on WDExxxx hard drives.
- Fixed a problem with 2.08 firmware on SMART-2SL Controller following a brief
power cycle causing the following false Array Accelerator POST error
messages:
1792-Slot x Drive Array - Valid data found in Array Accelerator
Data will automatically be written to
Drive Array.
1797-Slot x Drive Array - Array Accelerator Read Error Occurred
Array Accelerator disabled.
- Changed Flash algorithm to help prevent some intermittent ROM flash
failures on the SMART-2 family of controllers.
- Upgrade for DCHS0xx Drives from 5656 to 5858 to prevent false pre-failure notification
by Compaq Insight Manager
- Upgrade for WDE9100 drives from 1.35 to 1.40 to prevent slow seek time problems that
result in false pre-failure noitification by Compaq Insight Manager
- Upgrade for WDExxxx drives from 1.60 to 1.70 to prevent slow seek time problems that
result in false pre-failure noitification by Compaq Insight Manager
- Upgrade for MAX3xxx drives from 0813 to 0814 to enhance defect management
- Upgrade for ST34501W drives from AF03 to AF04 to enable drive Write-Cache.
(Applies to Workstations only)
NOTE: Firmware below preceded by an "*" is not included in the .INF
files due to space limitations in the systems partition.
CONTROLLER FIRMWARE
===================
SMART Controller version 2.26 (disk 1)
SMART-2 Controller version 2.14 (disk 1)
Fibre Array Controller version 1.14 (disk 1)
HARD DRIVES
===========
* version 0814 - model MAA3182SP, MAA3182SC, MAB3091SP, MAB3091SC, MAB3045SP,
MAB3045SC. (disk 4 )
* version B004 - model ST19101WC (disk 4 )
* version 1.40 - model WDE9100S (disk 4 )
* version 1.70 - model WDE2170, WDE2170W, WDE2170S, WDE4360, WDE4360W, WDE4360S (disk 4 )
* version AF04 - model ST34501W, ST34501WC (disk 4 )
version 5858 - model DCHS04Y, DCHS09Y, DCHS04U (disk 2 )
version 01C0 - model DGHS09U, DGHS09Y, DGHS18Y SCSI drives. (disk 2 )
* version 9A10 - model ST19171N, ST19171W, ST19171WC SCSI drives. (disk 3 )
* version 0940 - model ST32171N, ST32171W, ST34371N, ST34371W SCSI drives. (disk 4 )
* version 0942 - model ST32171WC, ST34371WC SCSI drives. (disk 4 & 8)
version 4343 - model DFHSS2W, DFHSS2F, DFHSS4W, DFHSS4F drives. (disk 2 )
* version L915 - model XP34300W [4GB] SCSI drives. (disk 2 )
* version L915 - model XP32150W [2GB] SCSI drives. (disk 2 )
* version 6317 - model ST32550N [2GB] SCSI drives. (disk 3 )
* version 6416 - model ST32550W [2GB] SCSI drives. (disk 3 )
* version 5217 - model ST15150N [4GB] SCSI drives. (disk 3 )
* version 6216 - model ST15150W [4GB] SCSI drives. (disk 3 )
TAPE DRIVES
===========
* version 4C0D - model 4322NP Compaq 2/8GB DAT. (disk 5)
* version 1214 - model C1536 Compaq 2/8GB DAT. (disk 5)
* version 4C08 - model 4326NP Compaq 4/16GB TurboDAT. (disk 5)
* version 0324 - model CTD8000R Compaq 4/16GB TurboDAT. (disk 5)
* version 0420 - model CTL96G-S Compaq 4/16GB TurboDAT Autoloader. (disk 5)
* version 4C04 - model 4586NP Compaq 4/16GB TurboDAT Autoloader. (disk 5)
CD STORAGE SYSTEM
=================
* version 3080 (disk 5)
NOTE: Multiple firmware versions exist for these products. This
ROMpaq utility will identify and upgrade the correct firmware to the
specific OEM tape hardware product.
HOW TO USE:
1. Obtain five (5) formatted 1.44-MB diskettes.
2. Download the SoftPaq to a directory on your hard drive and change
to that directory. The file that is downloaded is an executable with
a filename based on the SoftPaq Number above.
3. From that drive and directory, execute the downloaded file
and follow the on-screen instructions. You will be prompted to
insert the formatted diskettes in a drive to create the diskettes.
4. After the diskettes have been created, you may delete the
SoftPaq file downloaded in step 2.
5. The Options ROMPaq diskettes are self-booting diskettes. Place each
ROMPaq diskette into your drive A: diskette drive and power cycle your
system to begin updating the appropriate components.
Copyright 1998, Compaq Computer Corporation. All rights reserved.
Product names mentioned herein may be trademarks and/or registered trademarks
of their respective companies.
PaqPlace — Compaq SoftPaq driver and software preservation archive. Not affiliated with Compaq or Hewlett-Packard.
Compaq and SoftPaq are trademarks of Hewlett-Packard Development Company, L.P.
All software provided as-is. Use at your own risk.
|
Home
|