SOFTPAQ NUMBER: SP8008
PART NUMBER: 277294-001, 277295-001, 277296-001, 277297-001, 277298-001, 277299-001
FILE NAME: N/A
TITLE: Support Software for Novell Products
VERSION: 5.01 Rev A
LANGUAGE: English
CATEGORY: Systems/Drivers
PRODUCTS AFFECTED: Compaq ProSignia and ProLiant Servers
OPERATING SYSTEM: Novell NetWare 3.2
intraNetWare 4.11
intraNetWare SMP 4.11
NetWare SFT-III 4.1x
NetWare 5
SYSTEM CONFIGURATION: N/A
EFFECTIVE DATE: 15 September 1998
ELECTRONIC DISTRIBUTION ALLOWED: Yes
SOFTPAQ UTILITY VERSION: 2.x
SUPERSEDES: SP5701
DESCRIPTION: Creates the Support Software for Novell Products Diskettes (NSSD).
The NSSD diskettes contain NetWare and intraNetWare drivers, NetWare Loadable
Modules (NLMs), and support information to optimize the performance of NetWare and
intraNetWare on Compaq servers. This software enhances the performance of Compaq
options such as Compaq Drive Array controllers, Compaq 32-Bit SCSI-2 controllers,
and Compaq CD-ROM drives.
Enhancements/Fixes:
INSTALL UPDATES
CPQNSSU.NLM UPDATES
CPQNSSU.NLM v1.10 is a new client/server application that will update NSSD
drivers to a NetWare server. The CPQNSSU has the ability to gather a
list of Compaq drivers loaded on the server, the built-in intelligence
to decide if those drivers are current, and the option to update those
drivers, local or remote.
IMPORTANT: This version of the Compaq Support Software Utility does
not support the installation of NSSD from diskette media.
CPQCHW.NLM UPDATES
CPQCHW.NLM 1.10 is a new hardware discovery module that will gather
hardware information from a NetWare server and send it back to the
CPQNSSU.NLM using the Compaq Communication Module (CPQCOMM.NLM).
CPQCMODS.NLM UPDATES
CPQCMODS.NLM 1.20b is a new NetWare Loadable Module (NLM) that gathers
other modules loaded on a NetWAre server and communicates the
information back to the CPQNSSU.NLM using the Compaq Communication
Module (CPQCOMM.NLM).
CPQCOMM.NLM UPDATES
CPQCOMM.NLM v4.10 is a new NCP Extension Communications NetWare Loadable
Module (NLM) for the CPQNSSU.NLM. It allows the CPQNSSU.NLM to
communicate with other NLMs on local or remote servers.
CPQDOSLB.NLM UPDATES
CPQDOSLB.NLM v1.00 is a new remote DOS access NetWare Loadable Module
(NLM). It assists in file manipulation on a DOS partition of a
remote NetWare server. The information about remote DOS files
is sent/received using CPQCOMM.NLM.
CPQLIB.NLM UPDATES
CPQLIB.NLM v1.51a is the new Compaq Library NetWare Loadable Module
(NLM). It exports several functions that assist the CPQNSSU.NLM.
CPQNSSC.NLM UPDATES
CPQNSSC.NLM v1.31k is a new utility that assists NSSU.NLM with NCF files
and hardware information for driver installations.
CPQRBOOT.NLM UPDATES
CPQRBOOT.NLM v1.00 is a new module used to reboot the target server.
When the user selects to reboot the server, the CPQNSSU.NLM will
communicate with CPQRBOOT.NLM using the Compaq Communication
Module (CPQCOMM.NLM). CPQRBOOT.NLM will then reboot the server.
STORAGE UPDATES
CPQARRAY.HAM UPDATES
CPQARRAY.HAM v1.22 adds support for NetWare 5.
CPQARRAY.HAM v1.22 adds support for the SMART Array 3200 controller features.
CPQFC.HAM UPDATES
CPQFC.HAM v1.11 adds support for
- Long Wave Giga-Bit Interface Converter (GBIC)
- Single Mode Fibre Cabling
- Compaq 12-port Fibre Channel Hub
CPQSCSI.HAM UPDATES
CPQSCSI.HAM v1.22 adds support for NetWare 5.
CPQSCSI.HAM v1.22 adds support to negotiate Ultra speeds on
non-Hot Plug, non-Compaq disks on an internal cable.
CPQSCSI.HAM v1.22 fixes starving I/O requests.
CPQSHD.CDM UPDATES
CPQSHD.CDM v1.22 adds support for NetWare 5.
CPQSHD.CDM v1.22 removes Mount messages from console screen.
SERVER MANAGEMENT UPDATES
CPQHLTH.NLM UPDATES
CPQHLTH.NLM v4.02 adds support for NetWare 5.
CPQHLTH.NLM v4.02 adds support for the ProLiant 6500 Pentium II
Xeon models.
CPQIML.NLM UPDATES
CPQIML.NLM is a new NetWare Loadable Module (NLM) which allows
users to view and manage server event data stored in the Compaq
Integrated Management Log (IML). The utility also allows users
to view and manage server information displayed by the Compaq
Integrated Management Display (IMD).
NOTE: CPQIML.NLM v1.00 requires CPQHLTH.NLM v4.00 or later for
complete functionality. CPQIML.NLM v1.00 is compatible
with earlier versions of CPQHLTH.NLM; however, it will
only provide a restricted CPQIML feature set.
CPQMPK.PSM UPDATES
CPQMPK.PSM is a new Platform Support Module supporting Compaq
platforms running NetWare 5.
CPQONLIN.NLM UPDATES
CPQONLIN.NLM v2.31 adds support for the Compaq SMART Array 3200
controller features.
CPQONLIN.NLM requires two support modules to be loaded on NetWare 5
in order to warn the user that logical drive contains a volume
before allowing the user to delete it:
NWIDK.NLM - allows access to the NetWare Classic file system.
CPQONLIN will attempt to load this module automatically when the
Array Configuration Utility is selected.
NSS.NLM - allows access to the NSS volumes. CPQONLIN will give
the user the option of loading NSS.NLM when the Array Configuration
Utility is selected. If the user chooses not to load NSS.NLM,
CPQONLIN will not be able to warn the user if there is an NSS
volume on a logical drive before allowing the user to delete it.
CPQPOWER.NLM UPDATES
CPQPOWER.NLM is a new Health driver user interface utility that
displays redundant power subsystem status. In addition, the
utility incorporates the Compaq Power Down Manager which allows
configuration of the intelligent power switch.
CPQSBD.NLM UPDATES
CPQSBD.NLM v2.12 adds support for NetWare 5.
CPQSBD.NLM has been updated to allow a user to replace an adapter
after it has been hot-plug added.
CPQSBD.NLM v2.12 supports the PCI Hot Plug Button feature on the
ProLiant 7000 Pentium II Xeon models.
MISCELLANEOUS UPDATES
ADDITION OF 6TH DISK TO NSSD
NSSD has changed diskette structure to incorporate a sixth diskette
in order to accommodate current and future needs for Compaq's Networking
drivers. Currently included on NSSD are the Compaq Gigabit Ethernet
(N1000.LAN) drivers. In order to provide continuity between the two
Networking diskettes, the Networking I and Networking II/Client Support
deliverables have been moved to diskettes 5 and 6 accordingly.
The diskette structure as of NSSD 5.01 is:
Disk 1 Installation, DOS CD and SFT III Support
Disk 2 Documentation
Disk 3 Storage Support
Disk 4 Advanced Server Management and PCI Hot Plug Support
Disk 5 Networking Support I (current server networking products)
Disk 6 Networking Support II (non-shipping products) and
Network Client Support
NSSD DIRECTORY RESTRUCTURING
In an effort to continue providing support for NetWare 3.x, 4.x, and 5.x
platforms, it was realized that there was a need to redistribute files
in the Novell Support Software directories. The following restructuring
scheme has been implemented:
* Where support for all three operating systems is available with one
version of the driver, that driver is placed in its original location
as a "common file".
* Where special support is required for a particular version of NetWare,
those drivers are placed in the appropriate directory according to the
supported version of the operating system.
* For NetWare 3.x support, files are placed in a subdirectory of their
original location, named 3x.
* For NetWare 4.x support, files are placed in a subdirectory of their
original location, named 4x.
* For NetWare 5.x support, files are placed in a subdirectory of their
original location, named 5x.
* Where files are necessary for NetWare 3.x and 4.x support only, they
are placed in a subdirectory named 3x_4x.
Additionally, all DDFS driver support files (.DSK disk drivers) have
been moved into a directory named DSK. This allows for differentiation
between legacy support for DDFS drivers and support for newer NWPA
drivers.
Lastly, the DOS network support has moved from the DOS directory to the
\NETWORK\CLIENT directory to better reflect the nature of these drivers
and avoid confusion with the DOS CD-ROM drivers, currently located in
the DOS directory, when delivered in CD-based or network-install format.
DOCUMENTATION ENHANCEMENTS
The NSSD documentation is undergoing a series of enhancements to better
provide customers with a more robust and resourceful informational
product. In this release of NSSD, Driver Reference Forms have been
added and will contain the following:
* Release Information
* What's New
* Supported Hardware/Software
* Driver Description
* Installation Instructions
* Troubleshooting Information
* Historical Information
In addition to adding the Driver Reference Forms, we've have eliminated
the following files:
* HISTORY.RDM
* SFT3.RDM
As documentation enhancements occur, updates will be provided in
WHATSNEW.RDM.
Your comments and suggestions are welcomed at [email protected].
REMOVAL OF HISTORY.RDM
In an effort to streamline the information delivered in the NSSD
documentation, content contained in the HISTORY.RDM has been
incorporated into the new Driver Reference Forms. Removing
HISTORY.RDM prevents duplication of material and will reduce
the size of the readme files and the NSSD.HLP file.
A complete list of historical information is published in the
White Paper titled 'Historical Updates to Novell Drivers from
Compaq' available on Compaq's web site, http://www.compaq.com.
As of NSSD 5.01, please consult these documents to obtain
historical information for Compaq drivers.
REMOVAL OF SFT3.RDM
In an effort to streamline the information delivered in the NSSD
documentation, content contained in the SFT3.RDM has been
incorporated into the new Driver Reference Forms. Removing
SFT3.RDM prevents duplication of material and will reduce the
size of the readme files and the NSSD.HLP file.
As of NSSD 5.01, please consult the Driver Reference Forms for
information on the CPQMP.NLM driver.
Refer to the Driver Summary Chart for specific content layout of
the NSSD diskettes.
SUPPORTED SYSTEM ENVIRONMENT UPDATES
Novell Support Software no longer supports the NetWare 3.12 or
NetWare 4.10 environments.
HOW TO USE:
1. Download the SoftPaq to a directory on your hard drive and change
to that directory. The file that is downloaded is an executable with
a filename based on the SoftPaq Number above.
2. From that drive and directory, execute the downloaded file
and follow the on-screen instructions. You will be prompted to
insert the formatted diskettes in a drive to create the diskettes.
4. After the diskettes have been created, you may delete the
SoftPaq file downloaded in step 2.
5. For installation instructions, refer to INSTALL.RDM on diskette 2.
Copyright 1998, Compaq Computer Corporation. All rights reserved.
Product names mentioned herein may be trademarks and/or registered
trademarks of their respective companies.
PaqPlace — Compaq SoftPaq driver and software preservation archive. Not affiliated with Compaq or Hewlett-Packard.
Compaq and SoftPaq are trademarks of Hewlett-Packard Development Company, L.P.
All software provided as-is. Use at your own risk.
|
Home
|