SOFTPAQ NUMBER:  SP5736
PART NUMBER:  276029-007
FILE NAME:  N/A
TITLE:	Drive Array Advanced Diagnostics (DAAD)
VERSION:  1.44 Rev A
LANGUAGE:  English

CATEGORY:  Systems/Diagnostics-Setup

PRODUCTS AFFECTED:  All Compaq products that contain a Smart SCSI Array
		    Controller using SCSI hard drives.

OPERATING SYSTEM:  N/A

SYSTEM CONFIGURATION: N/A

EFFECTIVE DATE:  04/30/98

ELECTRONIC DISTRIBUTION ALLOWED:  Yes

SOFTPAQ UTILITY VERSION:  2.x

SUPERSEDES:  SP4430

DESCRIPTION:  Drive Array Advanced Diagnostics utility is a DOS based tool
	      designed to run on all Compaq products that contain a Smart
	      SCSI Array Controller using SCSI hard drives. The two main
	      functions of DAAD are to collect all possible information
	      about the array controllers in the system and generate a
	      list of detected problems.  This data can then be saved to a
	      file for analysis. In most cases, DAAD will provide enough
	      information to initiate problem resolution immediately.
	      DAAD consists of one (1) diskette:
		DRIVE ARRAY ADVANCED DIAGNOSTICS

Enhancements:

 - Display Cylinders, Heads, & Sectors/Track for Logical Parameter
   Table.  This can be found by selecting Logical Drive Configuration
   on the Inspect Menu.

 - Display Cylinders, Heads, & Sectors/Track for Drive Parameter Table.
   This can be found by selecting Logical Drive Identification on the
   Inspect Menu.

Fixes:

 - Fixed reporting of Identify Controller Configuration Error bits
   0,2,3,5-7.

 - Fixed Physical Drive State being simultaneously reported as
   "(Replacement)" and "(Wrong Replacement)".

 - Fixed reporting of rebuild aborts due to a READ error; they were
   incorrectly reported as a WRITE error.


HOW TO USE:

1.  Obtain a formatted 1.44-MB diskette.

2.  Download the SoftPaq to a directory on your hard drive and change
    to that directory.	The file that is downloaded is an executable
    with a filename based on the SoftPaq Number above.

3.  From that drive and directory, execute the downloaded file
    and follow the on-screen instructions.  You will be prompted to
    insert the formatted diskette in a drive to create the diskette.

4.  After the diskette has been created, you may delete the
    SoftPaq file downloaded in step 2.

5.  The DAAD diskette is self-booting.	Place the diskette into your
    drive A: diskette drive and power cycle your system to start the
    DAAD utility.

Copyright 1998, Compaq Computer Corporation.  All rights reserved.