PaqPlace   For your Compaq Compaq SoftPaq Driver & Software Archive
Home | Servers | Desktops | Notebooks | Workstations | Other | All SoftPaqs
Home > All SoftPaqs > SP20300

SP20300 — Systems ROMPaq Firmware Upgrade Diskette for Compaq ProLiant ML370 G2 Servers.

SoftPaq Number SP20300
Filename sp20300.exe
Size 588K
Date January 25, 2002
Version 4.01A
Operating System All
Products Affected Compaq ProLiant ML370 G2
Supersedes SP18961

  Download sp20300.exe  


Readme

SOFTPAQ NUMBER:  SP20300
PART NUMBER:  251311-002
FILE NAME:  SP20300.EXE
TITLE:  Systems ROMPaq Firmware Upgrade Diskette for Compaq ProLiant
        ML370 G2 Servers.

VERSION:  4.01A

LANGUAGE:  English

CATEGORY:  ROMPaqs

DIVISIONS:  Systems

PRODUCTS AFFECTED:  Compaq ProLiant ML370 G2

OPERATING SYSTEM:  N/A

SYSTEM CONFIGURATION:  N/A

PREREQUISITE:  N/A

EFFECTIVE DATE:  January 25, 2002

ELECTRONIC DISTRIBUTION ALLOWED:  Yes

SOFTPAQ UTILITY VERSION: 2.X

SUPERSEDES:  SP18961

DESCRIPTION:   This release provides updated system ROM images
               for the latest maintenance releases of Compaq
               ML370 G2 Servers.


New Features -


        ProLiant ML370 G2 ROM P25 (12/11/2001)
        ============================================

                Allow SmartStart to be able to control which device to boot
		from even if there is a ROMPAQ disk in the floppy drive.

		Added support for Windows.NET.

		Added some changes to speed up POST.

		Added prompt for administrator password when F9 is pressed after
		a warm boot.

		Changed POST to halt the system if a failed or missing VRM
		is detected.

		Added prompt for the administrator password when booting a CD
		with no emulation.

		Added message for the backup ROM being invalid.

		Added a check for mixed speed processors.  The system will
		now be halted if the processor speeds don't match.

		Added support for Serial Port Console Redirection (SPCR) table
		for Windows.NET.

		Added multiple function support for NC3134 and NC3122 NICs
		in RBSU.	

		Added support for NetWare 6.

		Added support for OpenUNIX 8.

		Added help text to RBSU to explain the Delayed choice for 
		the F1 prompt.
		
		Added in NC7132 NIC, NC7770 NIC, NC6770 NIC, and Smart Array 5312 
		names to RBSU.

	     	Don't allow more than 8 IPL devices to show up in RBSU.

		Added information panel for Quicklock option to RBSU.

		Added information for erasing NVRAM to RBSU.

		Added support so that the language only needs to be selected once
		between SmartStart and RBSU.  Previously, it had to be selected
		separately in each.




Problems Fixed -


        ProLiant ML370 G2 ROM P25 (12/11/2001)
        ============================================

                Fixed problem with USB entry in MP Mapped Mode.

		Fixed problem with system hanging on 101-IO ROM ERROR message. 
		
		Added correct messaging for the processor being detected in the
		wrong socket.  We were calling the processor socket a "slot."

		Fixed problem with NMI's corrupting serial number in NVRAM.

		Fixed problem with administrator password screen not being
		cleared fast enough when trying to boot to ROMPAQ disk.

		Fixed problem with some option ROMs hanging.

		Fixed a problem with an extra beep during POST.

		Fixed problem with NMI debug button not becoming enabled
		after setting the option in RBSU and warm booting.

		Fixed problem with CDRW media on 3rd party CDROM drives.

		Added fix to make sure that USB keyboard LEDs initialize
		to off.

		Fixed problem with NMI button not being sourced properly.

		Fixed problem with PS/2 mouse during installation of
		Windows 2000 when a USB keyboard is being used.

		Fixed problem with RBSU allowing the date/time and the
		language to be changed when NVRAM is locked.

		Corrected some of the NIC names in RBSU.

		Fixed some translations in RBSU.

		Fixed problem with redundant entries in the boot controller
		order.

		Corrected misspelling of "management" in RBSU.

		Fixed problem with some RBSU windows overlapping.

		Fixed problem where "SCSI network controller" will show up
		in IPL list if RBSU cannot find the name of a NIC card.

		Fixed problem where the administrator password is not
		being cleared when clearing NVRAM in RBSU.

		Fixed problem with NVRAM being locked without prompting
		for an administrator password when there is a bootable
		disk in the floppy drive.

		Fixed problems with the boot controller order when the
		CDROM drive is removed from the system.

		Fixed problem where RBSU allowed strings to be changed
		when NVRAM was locked.

		Make sure that CMOS gets cleared when maintenance switch
		is set.

		Fixed problem with Solaris not setting the ID for 
		the IOAPICs.		

		Fixed a problem where Netware 6 SP1 would hang attempting
		to down the server.





HOW TO USE:

1.  Obtain a formatted 1.44 MB diskette.

2.  Download the SoftPaq to a directory on your hard drive and change to that directory.
The file that is downloaded is SP20300.EXE.

3.  From that drive and directory, execute the SoftPaq file:
SP20300 [ENTER]
You will be prompted to place the formatted 1.44 MB diskette into a diskette drive to
create diskette.

4.  After the diskette is created, you may delete the downloaded file
SP20300.EXE if you wish.

5.  Refer to README.TXT on the diskette for instructions on installing and using the
software.

Copyright 2002, Compaq Computer Corporation.  All rights reserved.

Product names mentioned herein may be trademarks and/or registered trademarks of their
respective companies



PaqPlace — Compaq SoftPaq driver and software preservation archive. Not affiliated with Compaq or Hewlett-Packard.
Compaq and SoftPaq are trademarks of Hewlett-Packard Development Company, L.P.
All software provided as-is. Use at your own risk.
Home