Systems Updated: - ProSignia, ProSignia VS, ProSignia 200/300/500, Prosignia Server 720/740 - Proliant 800/850R/1000/1200/1500/1600/1850R/2000/2500/3000/4000/4500/5000/5500/ 6000/6500/7000/8000/8500/DL380/ML350/ML370/ML530/ML570/DL580, Rack-Mountable Proliant Servers or Systempro, Systempro/e, Systempro/LT, Systempro/XL Options Affected: - Compaq SMART-2 Family of Array Controllers - Compaq SMART Array 3100ES, 3200, 221, 431, 4250ES, 4200 and 5300 Array Controllers - Compaq Integrated SMART Array Controller - Compaq RA4X00 Controller - All Compaq 4.3 GB, 9.1 GB, 18.2 GB, 36 GB and 72 GB SCSI Server Hard Drives (S.M.A.R.T. Enabled) |
Readme
SOFTPAQ NUMBER: SP16277
PART NUMBER:
FILE NAME: N/A
TITLE: M&P Patch
VERSION: 1.50
LANGUAGE: English
CATEGORY: SoftPaqs
DIVISION: Systems
PRODUCTS AFFECTED:
Systems Updated:
- ProSignia, ProSignia VS, ProSignia 200/300/500, Prosignia Server 720/740
- Proliant 800/850R/1000/1200/1500/1600/1850R/2000/2500/3000/4000/4500/5000/5500/
6000/6500/7000/8000/8500/DL380/ML350/ML370/ML530/ML570/DL580, Rack-Mountable Proliant
Servers or Systempro, Systempro/e, Systempro/LT, Systempro/XL
Options Affected:
- Compaq SMART-2 Family of Array Controllers
- Compaq SMART Array 3100ES, 3200, 221, 431, 4250ES, 4200 and 5300 Array
Controllers
- Compaq Integrated SMART Array Controller
- Compaq RA4X00 Controller
- All Compaq 4.3 GB, 9.1 GB, 18.2 GB, 36 GB and 72 GB SCSI Server Hard Drives
(S.M.A.R.T. Enabled)
OPERATING SYSTEM: N/A
SYSTEM CONFIGURATION: N/A
EFFECTIVE DATE: March 5, 2001
ELECTRONIC DISTRIBUTION ALLOWED: Yes
SOFTPAQ UTILITY VERSION: 4.X
SUPERSEDES: N/A
DESCRIPTION: The M&P Patch Utility resets any false predictive
failure indicators and returns the drive from a falsely degraded
condition to a normal operating condition. This will also prevent
any future false predictive failure errors from occurring.
* NOTE: No Self Monitoring Analysis and Reporting Technology (S.M.A.R.T.)
attributes or values are changed so that any actual S.M.A.R.T.
predictive failures will remain triggered.
* NOTE: The M&P Patch Utility eliminates the traditional hard drive
M&P tests and associated thresholds. Compaq Insight Manager will show
these tests as N/A (Not Applicable) in the hard drive monitoring
section of the application. A future release of Compaq Insight Manager
will replace these test fields with the associated S.M.A.R.T.
predictive failure tests and values.
Disk 1 - M&P Patch Utility Version 1.50
* NOTE: This utility only applies to Compaq SCSI hard drives attached to Compaq
SMART Array Controllers. Hard drives attached to standard SCSI controllers
are not affected.
*Note : If you are planning to upgrade the hard drive firmware it is
important to perform the hard drive firmware upgrades by running Options ROMPaq
before running this utility. Running Options ROMPaq v2.62 or any earlier versions
can undo the changes made by this utility. If this happens, simply run
this utility again after completing the necessary firmware upgrades.
*Note: This version of the M&P patch will not affect drives attached to RA41XX,
Compaq will add this support to a future version of the M&P patch.
KNOWN ISSUES:
* Compaq Insight Manager will show the traditional hard drive M&P tests as N/A
(Not Applicable) in the hard drive monitoring section of the application. A
future release of Compaq Insight Manager will replace these test fields with
the associated S.M.A.R.T. predictive failure tests and values.
HOW TO USE:
1. Obtain one (1) formatted 1.44-MB diskettes.
2. Download the SoftPaq to a directory on your hard drive and change
to that directory. The file that is downloaded is an executable with
a filename based on the SoftPaq Number above.
3. From that drive and directory, execute the downloaded file
and follow the on-screen instructions. You will be prompted to
insert the formatted diskette in a drive to create the diskette.
4. After the diskette has been created, you may delete the
SoftPaq file downloaded in step 2.
5. The M&P Patch Utility diskette is a self-booting diskette. Place the
diskette into your drive A: diskette drive and power cycle your
system to apply the utility.
Copyright 2000, Compaq Computer Corporation. All rights reserved.
Product names mentioned herein may be trademarks and/or registered trademarks
of their respective companies.
PaqPlace — Compaq SoftPaq driver and software preservation archive. Not affiliated with Compaq or Hewlett-Packard.
Compaq and SoftPaq are trademarks of Hewlett-Packard Development Company, L.P.
All software provided as-is. Use at your own risk.
|
Home
|