PaqPlace   For your Compaq Compaq SoftPaq Driver & Software Archive
Home | Servers | Desktops | Notebooks | Workstations | Other | All SoftPaqs
Home > All SoftPaqs > SP14554

SP14554 — Japanese Novell Support Software Diskette (NSSD)

SoftPaq Number SP14554
Filename sp14554.exe
Size 4009K
Date June 20, 2000
Version 6.00 Rev A
Operating System Novell NetWare
Products Affected Compaq Server products
Supersedes SP13627

  Download sp14554.exe  


Readme

SOFTPAQ NUMBER:  SP14554
PART NUMBER:  127755-297, 127756-297, 127757-297, 127758-297, 127759-297,
              127760-297, 127761-297
FILE NAME:  NSSD
TITLE:	Japanese Novell Support Software Diskette (NSSD)
VERSION:  6.00 Rev A
LANGUAGE:   Japanese

CATEGORY:  Drivers

DIVISIONS:  Systems

PRODUCTS AFFECTED:  Compaq Server products

OPERATING SYSTEM:  Novell NetWare 3.2J
                   intraNetWare
                   intraNetWare SMP
                   NetWare 4.2
                   NetWare SFT-III
                   NetWare 5.x (Japanese) 

SYSTEM CONFIGURATION:  N/A

PREREQUISITES:  N/A

EFFECTIVE DATE:  June 20, 2000

ELECTRONIC DISTRIBUTION ALLOWED:  Yes

SOFTPAQ UTILITY VERSION:  2.x

SUPERSEDES:  SP13627

DESCRIPTION:  This SoftPaq is for Japanese products, and cannot be run 
in United States mode.  It creates seven diskettes.
The NSSD diskettes contain NetWare and intraNetWare drivers, NetWare 
Loadable Modules (NLMs), and support information to optimize the 
performance of NetWare and IntranetWare on Compaq servers.  
This software enhances the performance of Compaq options such as Compaq 
Drive Array controllers, Compaq 32-Bit SCSI-2 controllers, and Compaq 
CD-ROM drives.

Enhancements/Fixes in Version 6.00 Rev A:

This release of the Support Software for Novell Products (NSSD) primarily
supports the following new products:

   - Compaq RAID LC2 Controller 

The following Compaq drivers were updated:

CPQARRAY.HAM Version 2.08 - NSSD 6.00A
- Added support for the following new controller:
  * Compaq RAID LC2 Controller 

CPQFC.HAM Version 2.40 - NSSD 6.00A
- Added support for the Storage Works Fibre Channel Arbitrated Loop Switch
  and SW FC-AL Switch 3-Port Expansion Module.
- Added support for Compaq StorageWorks MA6000 subsystem.
- Added support for automatic failback in cluster or other multi-initiator
  configurations that are also configured with multi-path or redundant 
  storage paths to RA4X00.

CPQNSSU.NLM Version 1.49a - NSSD 6.00A
- Moved IDE support from diskette #3 to diskette #7.

CPQONLIN.NLM Version 2.45 - NSSD 6.00A
- Added limited support for Selective Storage Presentation.
- Added future support for RAID ADG.

CPQRSO.HAM Version 1.40 - NSSD 6.00A
- Extended delay time to allow a longer load time for the Compaq Server 
  Health Driver (CPQHLTH).

Your suggestions and feedback are welcome at [email protected].

HOW TO USE

1. Obtain seven (7) formatted 1.44 MB diskettes.

2. Download the SoftPaq to a directory on your hard drive and change 
to that directory.  The file that is downloaded is an executable with 
a filename based on the SoftPaq Number above.

3.  From that drive and directory, execute the downloaded file 
and follow the on-screen instructions.  You will be prompted to 
insert the formatted diskettes in a drive to create the diskettes.

4.  After the diskettes have been created, you may delete the  
SoftPaq file downloaded in step 2.

5. For installation instructions, refer to READ1ST.RDM and WHATSNEW.RDM 
on the created diskettes.

Copyright 2000, Compaq Computer Corporation.  All rights reserved.

Product names mentioned herein may be trademarks and/or registered 
trademarks of their respective companies.



PaqPlace — Compaq SoftPaq driver and software preservation archive. Not affiliated with Compaq or Hewlett-Packard.
Compaq and SoftPaq are trademarks of Hewlett-Packard Development Company, L.P.
All software provided as-is. Use at your own risk.
Home