SOFTPAQ NUMBER: SP14375
PART NUMBER: N/A
FILE NAME: N/A
TITLE: Compaq Insight Manager Agents and Tools - SCO UnixWare 7 NonStop(TM) Clusters
VERSION: 4.90a
LANGUAGE: English
CATEGORY: Software Solutions
DIVISIONS: Systems
PRODUCTS AFFECTED: Compaq Servers running SCO UnixWare 7
OPERATING SYSTEM: SCO UnixWare 7.1.1
SYSTEM CONFIGURATION: N/A
PREREQUISITES: - Compaq Enhanced Feature Supplement (EFS) for
SCO UnixWare 7, Version 7.38
The nsc package - Version 7.1.1 or 7.1.1b
EFFECTIVE DATE: September 1, 2000
ELECTRONIC DISTRIBUTION ALLOWED: Yes
SOFTPAQ UTILITY VERSION: 4.1
SUPERSEDES: nscups, nscvu, cmafdtn, cmastor, cmanic, cmasvr versions 4.80.
DESCRIPTION: Creates diskettes containing Compaq Insight
Manager Agents and Tools - SCO UnixWare 7 NonStop(TM) Clusters, Version 4.90a.
IMPORTANT: This softpaq can be installed on the 7.1.1 or later
versions of SCO UnixWare 7 NonStop Clusters. It upgrades the
version 4.80 CIM agents and tools or installs an initial version of CIM Agents and Tools
for SCO UnixWare 7 NonStop Clusters version 7.1.1.
HOW TO USE:
Perform steps 1-5 under DOS, Microsoft Windows 3.1, Windows95 or Windows NT.
Perform steps 6-9 under SCO UnixWare 7 NonStop Clusters.
1. Obtain 4 IBM-formatted 1.44-MB diskettes.
2. Download the SoftPaq to a clean directory on your hard drive
and change to that directory. The downloaded file is an executable
with a filename based on the SoftPaq Number above.
3. From that drive and directory, execute the downloaded file
and follow the on-screen instructions. Seven files will be created:
SP14375.TXT, SP14375._01, SP14375._02, SP14375._03, SP14375._04,
sp14375.cva, and QRST5.EXE.
4. Execute QRST5.EXE and at the prompt, insert the formatted
diskettes as prompted in the diskette drive to create the four diskettes
containing Compaq Insight Manager Agents - SCO UnixWare 7 NonStop Clusters,
Version 4.90a.
Label the diskettes with their numbered sequence.
The first diskette contains the following:
* nsc1013, which is required for the nscccm package.
* nscvu, the NonStop Clusters Verification Utility.
* nscups, the NonStop Clusters Uninterruptible Power Supply utility.
* nscccm, the Common Cluster MIB, which must be installed.
The second diskette contains cmafdtn, the Foundation Agents package.
The third diskette contains cmastor, the Storage Agents package.
The fourth diskette contains the following packages:
* cmasvr, the Server Agents package.
* cmanic, the Networking Agents package.
5. After the diskettes have been created, you can delete the
SoftPaq file downloaded in step 2 and the files unpacked in step 3.
6. To install the Compaq Insight Manager Agents - SCO UnixWare 7 NonStop
Clusters, log into your cluster as root.
7. Ensure that the EFS drivers are version 7.38 or higher by
issuing one of the following commands :
For Compaq Health Driver Update, enter
# pkginfo -l ptfcpqw
8. Insert the first newly created diskette into the cluster's default diskette
drive and enter:
pkgadd -d diskette1
Select all packages, and follow the on-screen directions.
Ignore any instructions concerning the download on nsc1013.
9. Insert the second floppy diskette, and enter:
pkgadd -d diskette1
Select all packages, and follow the on-screen directions.
10. Insert the third floppy diskette, and enter:
pkgadd -d diskette1 cmastor
Follow the on-screen directions.
11. Insert the last floppy diskette, and enter:
pkgadd -d diskette1 cmasvr cmanic
Follow the on-screen instructions.
12. Remove the last of the four diskettes.
----------Notes-------------------------------------------------
ASR Notes:
Do not install the EFS Compaq Advanced Server Recovery ptfcpqasr package.
Uninstall the ptfcpqasr package if it has been previously installed.
Ensure that the Advanced Server Recovery Option has been disabled.
to disable ASR, press F10 when prompted during the boot and
select System Configuration-->Configure Hardware-->Review or
Modify Hardware Settings-->Step 3: View or Edit Details.
Scroll to the Embedded - Automatic Server Recovery (ASR)
section and set the Automatic Server Recovery option to disabled.
Follow the on-screen instructions to save and exit then reboot
the system.
NSCVU Notes:
Refer to the nscvu(1M) manual page for usage information.
The nscvu command:
Outputs the incorrect value of cache for ML330 systems.
Can take as long as 30 minutes to display system information on systems with a large number of
mounts.
Can show multiple identical mount points on fiber-connected storage systems that use a large
number of mounts.
Is not supported on RSO configurations.
Can provide incorrect results if a root node is down.
Can take a long time to execute or start failover testing on a system with a large number of
mounts.
Power Management Notes:
Configure UPS-initiated shutdown by modifying the os_shutdown, ups_serial_port, and
ups_log_file parameters in the /opt/compaq/etc/nscupsd.cfg configuration file.
os_shutdown
Specifies the battery backup power remaining when a cluster-wide shutdown is initiated. For
example, an entry of os_shutdown=15 indicates that a cluster-wide shutdown is initiated when
the UPS has 15 minutes of battery backup power remaining. Measure the time required for a
clean shutdown of the cluster under peak operating conditions to ensure that the shutdown time
is adequate.
ups_log_file
Specifies the file that contains event information related to UPS state transitions. The default
parameter is /var/spool/compaq/nscupsd.log and should not be modified.
ups_serial_port
Specifies a list of ports that are separated by colons and semicolons. This list specifies the
serial ports to which the UPSs are connected and the combination of UPS signals for shutting
down the cluster.
Colon-separated serial ports create a pair of UPSs in which both of the UPSs must signal that
they are low on power before a cluster shuts down. Such a group of UPSs are referred to as
logical UPSs. A logical UPS identifies UPSs that are grouped together to provide redundant
power to a cluster. The drain of a single UPS within a logical UPS should not result in the loss of
any key cluster resources.
Semicolon-separated serial ports identify a list of UPSs or logical UPSs. A low-power indication
by any of those UPSs results in a cluster-wide shutdown. This parameter is used when a cluster
spans multiple power domains and the loss of any one domain results in a cluster-wide shutdown
to protect the cluster.
NOTE: A serial connection to a UPS is used in determining shutdown if the node with the
serial port is an active member in the cluster.
Example ups_serial_port Configurations
For a two-node cluster or single-rack cluster with two UPSs, the cluster should shut down when both
UPSs are low on power. To have both UPSs signal that they are low before shutting down the cluster,
combine both UPSs into a single logical UPS. This results in a ups_serial_port configuration of:
ups_serial_port=/dev/tty00.1:/dev/tty00.2
Where /dev/tty00.1 is the device identifier for the node 1 serial port tied to UPS1 and
/dev/tty00.2 is the device identifier for the node 2 serial port tied to UPS2.
In a multiple-rack cluster that uses fully redundant power in all key cluster components, the cluster
should shut down only if both UPSs in a single rack lose power. For both UPSs within a rack to signal
that they are low before shutting down the cluster, both UPSs within a rack are joined into a single
logical UPS. This results in an ups_serial_port configuration of:
ups_serial_port=A:B;C:D;
In which case the following is true:
A is the device identifier for the node serial port tied to UPS1A (/dev/tty00.1 for port 0 on node 1)
B is by the device identifier for the node serial port tied to UPS1B (/dev/tty00.2 for port 0 on node 2)
C is the device identifier for the node serial port tied to UPS2A (/dev/tty01.1 for port 1 on node 1)
D is by the device identifier for the node serial port tied to UPS2B (/dev/tty01.2 for port 1 on node
2)
Starting the UPS-Initiated Shutdown Software
After UPS-initiated shutdown has been configured as described in the preceding sections, restart the
UPS daemon by entering the following two commands:
/etc/init.d/nscups stop
/etc/init.d/nscups start
CIM Agent Notes:
* Agent startup can take up to 15 minutes when a node is rebooted.
* Agent startup can take up to 10 minutes per node at CIM installation.
* Use the following command syntax to perform the agent start or stop operation in the background:
/etc/init.d/cpqsnmp start | stop
* Use the following command syntax to perform the agent start or stop operation on a specific node:
/etc/init.d/cpqsnmp start_for | stop_for <node>
* Use the following command syntax to operate on a specific node:
/etc/init.d/cpqsnmp start_for/stop_for <node>
* Occasionally, not all daemons on all nodes will start properly
upon initial installation. If this situation occurs, either
reboot the cluster, or enter the following commands:
1. Enter:
onall /etc/init.d/cpqsnmp stop_for
2. Wait five minutes, then enter
onall /etc/init.d/snmp_node stop
3. Wait one hour, then enter:
onall /etc/init.d/cpqsnmp start_for
A known problem exists where heavy web use may cause the web daemon
to consume excessive resources. If this should occur, stop the daemon
with the following command:
onall /etc/init.d/cmaweb stop.
You can prevent the daemon from starting at boot time with the following command
mv /etc/init.d/cmaweb /etc/init.d/cmaweb.disabled.
* The cache size is incorrectly displayed for ML330 systems.
* In a terminal window on a graphical console, the pkgadd cmafdtn
command, which relies on having /sbin in the PATH variable will not work properly.
To correct this, set the PATH environmental variable before executing
the pkgadd command. The following is a Bourne Shell example:
# PATH=$PATH:/sbin
# export PATH
* CIM may not show all of the health information for node 2 of a IP
interconnect system with NSC 7.1.1+IP without SCO PTF nsc1011.
------------------------------------------------------------------
Copyright 2000 Compaq Computer Corporation.
Product names mentioned herein may be trademarks and/or registered
trademarks of their respective companies.
PaqPlace — Compaq SoftPaq driver and software preservation archive. Not affiliated with Compaq or Hewlett-Packard.
Compaq and SoftPaq are trademarks of Hewlett-Packard Development Company, L.P.
All software provided as-is. Use at your own risk.
|
Home
|