| PaqPlace
For your Compaq |
Compaq SoftPaq Driver & Software Archive |
|
|
|
SP12987 — Options ROMPaq
| SoftPaq Number |
SP12987 |
| Filename |
sp12987.exe |
| Size |
15917K |
| Date |
September 19, 2000 |
| Version |
2.62 Rev A |
| Operating System |
All |
| Products Affected |
Systems Updated: - ProSignia, ProSignia VS, ProSignia 200/300/500, Prosignia Server 720/740 - Proliant 800/850R/1000/1200/1500/1600/1850R/2000/2500/3000/4000/4500/5000/5500/ 6000/6500/7000/8000/8500/DL380/ML350/ML370/ML530/DL580, Rack-Mountable Proliant Servers or Systempro, Systempro/e, Systempro/LT, Systempro/XL Options Affected: - Compaq SMART-2 Family of Array Controllers - Compaq SMART Array 3100ES, 3200, 221, 4250ES, 4200 Array Controllers - Compaq Integrated SMART Array Controller - Compaq RA4000 Controller - Compaq SCSI Hard Drives attached to the above Compaq Array Controllers - Compaq SCSI Hard Drives attached to Compaq Non-Array Controllers. - Compaq CD Storage System |
| Supersedes |
SP12983 (Full release of Options ROMPaq 2.59) |
Readme
SOFTPAQ NUMBER: sp12987
PART NUMBER: 127567us
FILE NAME: N/A
TITLE: Options ROMPaq
VERSION: 2.62 Rev A
LANGUAGE: English
CATEGORY: ROMPaqs
DIVISION: Systems
PRODUCTS AFFECTED:
Systems Updated:
- ProSignia, ProSignia VS, ProSignia 200/300/500, Prosignia Server 720/740
- Proliant 800/850R/1000/1200/1500/1600/1850R/2000/2500/3000/4000/4500/5000/5500/
6000/6500/7000/8000/8500/DL380/ML350/ML370/ML530/DL580, Rack-Mountable Proliant
Servers or Systempro, Systempro/e, Systempro/LT, Systempro/XL
Options Affected:
- Compaq SMART-2 Family of Array Controllers
- Compaq SMART Array 3100ES, 3200, 221, 4250ES, 4200 Array Controllers
- Compaq Integrated SMART Array Controller
- Compaq RA4000 Controller
- Compaq SCSI Hard Drives attached to the above Compaq Array Controllers
- Compaq SCSI Hard Drives attached to Compaq Non-Array Controllers.
- Compaq CD Storage System
OPERATING SYSTEM: N/A
SYSTEM CONFIGURATION: N/A
EFFECTIVE DATE: September 19, 2000
ELECTRONIC DISTRIBUTION ALLOWED: Yes
SOFTPAQ UTILITY VERSION: 4.X
SUPERSEDES: SP12983 (Full release of Options ROMPaq 2.59)
DESCRIPTION: The Options ROMPaq diskettes allow a user to
upgrade the ROM Firmware images for Compaq System Product Options. The
Options ROMPaq consists of twelve (12) diskettes:
Disk 1 - Options ROMPaq Firmware Upgrade Diskette for
the Compaq SMART-2 Family, SMART Array 3100ES,
3200, 221, 4200, 4250ES and Integrated SMART
Array Controllers.
Disk 2 - Options ROMPaq Firmware Upgrade Diskette for
Compaq RA4X00 Controller
Disk 3 - Options ROMPaq Firmware Upgrade Diskette for
Compaq SCSI Hard Drives
Disk 4 - Options ROMPaq Firmware Upgrade Diskette for
Compaq SCSI Hard Drives
Disk 5 - Options ROMPaq Firmware Upgrade Diskette for
Compaq SCSI Hard Drives
Disk 6 - Options ROMPaq Firmware Upgrade Diskette for
Compaq SCSI Hard Drives
Disk 7 - Options ROMPaq Firmware Upgrade Diskette for
Compaq SCSI Hard Drives
Disk 8 - Options ROMPaq Firmware Upgrade Diskette for
Compaq SCSI Hard Drives attached to Compaq
RA4X00 Controllers.
Disk 9 - Options ROMPaq Firmware Upgrade Diskette for
Compaq SCSI Hard Drives attached to Compaq
RA4X00 Controllers.
Disk 10 - Options ROMPaq Firmware Upgrade Diskette for
Compaq SCSI Hard Drives attached to Compaq
RA4X00 Controllers.
Disk 11 - Options ROMPaq Firmware Upgrade Diskette for
Compaq SCSI Hard Drives attached to Compaq
RA4X00 Controllers.
Disk 12 - Options ROMPaq Firmware Upgrade Diskette for
Compaq SCSI Hard Drives attached to Compaq
RA4X00 Controllers.
* NOTE: This Option ROMPaq does not contain firmware images for any
Compaq tape drives. Obtain the latest Tape Options ROMPaq
from the Compaq Web site to get the latest tape drive
firmware from Compaq.
* NOTE: This Option ROMPaq does not contain firmware images for the
Compaq SMART Controller. Obtain SoftPaq SP8050 to get firmware
for this controller.
* NOTE: ****BOOT FROM DISKS 1, 2, & 3 TO IDENTIFY ALL SUPPORTED DEVICES****
Enhancements/Fixes:
- Upgrade RA4000 controller F/W from v2.54 to v2.58
- Added support for Smart Array 431 controller.
- Changed Fibre Channel controller name from "RA4000" to "RA4X00".
- Added support to update Monitor and Performance threshold limits for
the following hard drives:
Seagate:
AA0181178B, AA0182178C, AB00411792, AB00421793, AB00911790,
AB00921791, BB00411C48, BB00421793, BB00911C49, BB00921791
AA03631AC6, AB00931B92, AB01831AC4, BA03611C9B, BB00911CA0,
BB00921B91, BB01811C9C, BB01821AC3
AD009322B9, AD018322BC, AC036322C2, BD009122BA, BD009222BB,
BD018122C0, BD018222C1, BC036122C3
BC01821938, BD00411933, BD00421936, BD00911934, BD00921937,
HC0183172A, HC01841729, HD00431731, HD00441730, HD0093172C.
HD0094172B
HD00931C35
IBM:
DCHS04U, DCSH04Y, DCSH04W, DCSH04Z, DCHS09U, DCSH09Y,
DCSH09W, DCSH09Z
Western Digital:
HB00931B93, HB01831B95
Fujitsu:
AB009322B4, AB018322B6, AD009322C5, AD018322C8, BB00912301,
BB009222B5, BB018122B7, BB018222B8, BD009122C6, BD009222C7,
BD018122C9, BD018222CA
Quantum:
AC03632378, AD00932372, AD01832375, BC0367237A, BD00912578,
BD00962373, BD00972374, BD01812579, BD01862376, BD01872377
- Upgraded firmware for the following hard drives:
Seagate:
AD009322B9, AD018322BC, AC036322C2 from 3A08 to 3A09
BD009122BA, BD009222BB, BD018122C0 from 3B08 to 3B09
BD018222C1, BC036122C3 from 3B08 to 3B09
BC01821938 from 3B02 to 3B06
BD00411933, BD00421936 from 3B02 to 3B06
BD00911934, BD00921937 from 3B02 to 3B06
HC0183172A, HC01841729 from 3208 to 3212
HD00431731, HD00441730 from 3208 to 3212
HD0093172C. HD0094172B from 3208 to 3212
- Removed model support for the Seagate BC01811935 hard drive.
- Added two new Quantum drive models:
BD00962373, BD01862376
- Added a warning for a F/W downgrade of a RA4X00 controller from v2.54 or
later to a F/W version prior to v2.54, which may result in loss of array
configuration information and data. The text of the message follows:
The array configuration for one or more RA4X00 controllers may
no longer be compatible with the new firmware. Use ACU to
recreate each array volume with the original configuration or
upgrade the RA4X00 controllers back to the previous firmware
revision. Failure to do so may result in the loss of data.
CONTROLLER FIRMWARE
===================
SMART-2 Family and SMART
Array 221 Controller version 4.44 (diskette 1)
SMART Array 3x00 Controller version 4.44 (diskette 1)
Integrated SMART Array
Controller version 1.42 (diskette 1)
Smart Array 4200 and Smart
Array 4250ES Controller version 1.30 (diskette 1)
RA4X00 Controller version 2.58 (diskette 2)
HARD DRIVE FIRMWARE
===================
Diskette 3 & 8:
3B06 Seagate BC01821938
3B06 Seagate BD00411933, BD00421936
3B06 Seagate BD00911934, BD00921937
3212 Seagate HD00441730, HD00431731
3212 Seagate HD0094172B, HD0093172C
Diskette 4:
S99C IBM DDRS345
S99C IBM DDRS391
Diskette 4 & 9:
BCJE Quantum BD00912578, BD01812579
BCJE Quantum BD00972374, BD01872377, BC0367237A,
BD00962373, BD01862376.
5858 IBM DCHS04Y, DCHS04W, DCHS04U,
DCHS04Z, DCHS09Y, DCHS09W,
DCHS09U, DCHS09Z.
03F1 IBM DGHS09U, DGHS09Y, DGHS18Y
Diskette 5 & 10:
3AS7 Seagate AB00931B92, AB01831AC4,
AA03631AC6
3BS7 Seagate BB00911CA0, BB00921B91, BB01811C9C,
BB01821AC3, BA03611C9B.
A195 WD HB00931B93, HB01831B95
AF04 Seagate ST34501W, ST34501WC
1400 WD WDE9100S
1700 WD WDE4360, WDE4360W, WDE4360S
Diskette 6 & 11:
3A09 Seagate AD009322B9
3A09 Seagate AD018322BC
3B09 Seagate BD009122BA, BD009222BB
3B09 Seagate BD018122C0, BD018222C1
0814 Fujitsu MAA3182SP, MAA3182SC, MAB3091SP,
MAB3091SC, MAB3045SP, MAB3045SC
Diskette 7 & 12:
3212 Seagate HC01841729, HC0183172A
ACJC Quantum AD00932372, AD01832375, AC03632378
3B09 Seagate BC036122C3
3A09 Seagate AC036322C2
KNOWN ISSUES:
HOW TO USE:
1. Obtain twelve (12) formatted 1.44-MB diskettes.
2. Download the SoftPaq to a directory on your hard drive and change
to that directory. The file that is downloaded is an executable with
a filename based on the SoftPaq Number above.
3. From that drive and directory, execute the downloaded file
and follow the on-screen instructions. You will be prompted to
insert the formatted diskettes in a drive to create the diskettes.
4. After the diskettes have been created, you may delete the
SoftPaq file downloaded in step 2.
5. The Options ROMPaq diskettes are self-booting diskettes. Place each
ROMPaq diskette into your drive A: diskette drive and power cycle your
system to begin updating the appropriate components.
****BOOT FROM DISKS 1, 2, & 3 TO IDENTIFY ALL SUPPORTED DEVICES****
Copyright 2000, Compaq Computer Corporation. All rights reserved.
Product names mentioned herein may be trademarks and/or registered trademarks
of their respective companies.
PaqPlace — Compaq SoftPaq driver and software preservation archive. Not affiliated with Compaq or Hewlett-Packard.
Compaq and SoftPaq are trademarks of Hewlett-Packard Development Company, L.P.