SOFTPAQ NUMBER: SP10562
PART NUMBER: N/A
FILE NAME: N/A
TITLE: Workstations Mylex Array Controller Firmware/BIOS Upgrade
VERSION: 4.07-0-29
LANGUAGE: English
CATEGORY: ROMPaqs
DIVISIONS: Workstations
PRODUCTS AFFECTED: Compaq Professional Workstations AP400, AP500, SP700
OPERATING SYSTEM: Microsoft Windows NT 4.0
SYSTEM CONFIGURATION: Mylex AcceleRAID 150 Array Conroller installed
PREREQUISITES: N/A
EFFECTIVE DATE: July 19, 1999
ELECTRONIC DISTRIBUTION ALLOWED: Yes
SOFTPAQ UTILITY VERSION: 2.x
SUPERSEDES: N/A
DESCRIPTION: Unpacks the files needed to flash the code on the Mylex
Array Controller.
This version of the Firmware/BIOS is an upgrade from the original version
shipping on the Mylex AcceleRAID 150 Array Controller.
Updates the FW to 4.07-0-29 and BCU to 1.00-16
NOTE:
To verify the present FW/BIOS versions on the card,
copy the DAC960fl.exe found on the Mylex CD under Utility/utils
to a bootable Diskette.
Boot to the Diskette and Run DAC960FL -d. The -d switch will display
the details of the Boot Block, BIOS, Firmware, BCU, and Diagnostics that
are flashed on the controller. Use the information on the screen to
verify that the controller needs to be upgraded to the versions above.
Enhancements/Fixes:
Firmware Changes from 4.07-0-27 to 4.07-0-29
- The controller now stops a rebuild after a new configuration is made.
- The Start/Stop command now detects a new drive when replacing an Offline
drive.
- GAM now updates the Miscellaneous Error Counter on a Check Condition when a
hard disk is jumpered in Write Protect mode.
- Boots to Installation Abort when 2 or more drives fail to start up.
- The controller now attempts a synchronous negotiation with synchronous capable
non-disk devices.
- Corrects possible incorrect data that could be passed to the calling
application when setup as follows: Raid 0, cache segment is 8KB and Stripe is
(8k or 64k) with Read Ahead turned on while doing a sequential read during an
OFFLINE drive.
- A change made to begin Background Initialization on the next write operation
following a configuration update.
RAID EzAssist version 1.00-9 to 1.00-16 change notes
- Ezassist now creates RAID 0+1 for 3 or more drives when performance is chosen
under Assisted Configuration.
- A pop-up dialog with "Add Capacity Stabilizing" message is displayed to allow
the Add Capacity module to kick in.
- Ezassist now displays the correct cache line sizes following cache line
changes.
- The System will now support adding more drives to a pack of an array that
already has 32 system drives.
- Prevents Non-disk devices being turned to Spares.
HOW TO USE:
1. Download the SoftPaq to a directory on your hard drive and change
to that directory. The file that is downloaded is an executable with
a filename based on the SoftPaq Number above.
2. From that drive and directory, execute the self extracting downloaded file.
4. Copy the files to a Diskette.
5. For installation instructions, see the README.TXT file.
Copyright 1999, Compaq Computer Corporation. All rights reserved.
Product names mentioned herein may be trademarks and/or registered trademarks
of their respective companies.
PaqPlace — Compaq SoftPaq driver and software preservation archive. Not affiliated with Compaq or Hewlett-Packard.
Compaq and SoftPaq are trademarks of Hewlett-Packard Development Company, L.P.
All software provided as-is. Use at your own risk.
|
Home
|